PST & PSS & PSH SERIES PROGRAMMABLE POWER SUPPLY
PROGRAMMER MANUAL
⎯ 17 ⎯
Table 4: Miscellaneous Commands
*IDN? Returns instrument identification.
*OPC Reports when operation is complete by setting
the Operation Complete bit in SESR.
*OPC? Reports when operation is complete. Same as
*OPC except returns a 1 to the output queue
and dose not set the SESR bit.
*RCL ★Recall the setting data from the memory
which previous saved.
*RST Resets the protection levels and states, resets
the current and voltage levels to zero, sets the
output off, and sets memory section to 00.
*SAV ★Saves the setting data to memory.
*TST? Initiates internal self-test and reports results.
*WAI Wait to continue. This command forces
sequential operation of commands. This
command is required by IEEE-488.1-1987.
The power supply, however, forces sequential
operation of commands by design.
:SYSTem:AUTO:CYCLe
<NR1>
★Set number of times of execution.
:SYSTem:AUTO:CYCLe ? ★Query the setting of the number of times of
execution.
PST & PSS & PSH SERIES PROGRAMMABLE POWER SUPPLY
PROGRAMMER MANUAL
⎯ 18 ⎯
:SYSTem:AUTO:DELay
<NR1>
★ Set the delay time under the current
responding memory status.
:SYSTem:AUTO:DELay ? ★Query the setting of the delay time under
the current responding memory status.
:SYSTem:AUTO:END
<NR1>
★ Set the end memory section for auto
execute continuously.
:SYSTem:AUTO:END ? ★Query the end memory section for auto
execute continuously.
:SYSTem:AUTO:STARt
<NR1>
★ Set the start memory section for auto
execute continuously.
:SYSTem:AUTO:STARt ? ★Query the start memory section for auto
execute continuously.
:SYSTem:AUTO:STATe
<Boolean>
★Sets Auto sequence on or off.
:SYSTem:AUTO:STATe ? ★Returns Auto Sequence mode on or off.
:SYSTem:ERRor ? Read the next item from the error/event
queue.
:SYSTem:MEMory? ★Query the last memory location
:SYSTem:VERSion? Returns the SCPI version level.
Remark: The mark “★” means the PSS and PSH do not have the