GDS-806/810/820/840 Programming Manual
28
:AUToset
Perform an automatic setup in order to optimize the acquisition parameters.
Syntax
:AUToset
:CHANnel<X>:BWLimit
Enable or disable the bandwidth limit function.
Syntax
:CHANnel<X>:BWLimit {0|1}
:CHANnel<X>:BWLimit?
Arguments
<X>Specify the channel number (1|2)
0Disable bandwidth limit 1Enable bandwidth limit
Returns <NR1>
:CHANnel<X>:COUPling
Select the different coupling states for the oscilloscope.
Syntax
:CHANnel<X>:COUPling {0|1|2}
:CHANnel<X>:COUPling?
Arguments
<X>Specify the channel number (1|2)
0Place scope in AC coupling state 1Place scope in DC coupling state
2Place scope in grounding state
Returns
<NR1>