Gw-instek AFG-2225 User Manual Manuel d'utilisateur Page 203

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 301
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 202
REMOTE INTERFACE
203
Sets frequency to 2kHz and sets the amplitude and
offset to the maximum.
SOURce[1|2]:APPLy:RAMP
Source Specific
Command
Outputs a ramp wave from the selected channel
when the command has executed. Frequency,
amplitude and offset can also be set. The
symmetry is set to 50%.
SOURce[1|2]:APPLy:RAMP [<frequency>
[,<amplitude> [,<offset>] ]]
<frequency>
1μHz~1MHz
<amplitude>
1mVpp~10Vpp (50)
<offset>
-4.99V~4.99V (50)
SOUR1:APPL:RAMP 2KHZ,MAX,MAX
Sets frequency to 2kHz and sets the amplitude and
offset to the maximum.
SOURce[1|2]:APPLy:PULSe
Source Specific
Command
Outputs a pulse waveform from the selected
channel when the command has executed.
Frequency, amplitude and offset can also be set.
The PW settings from the SOURce[1|2]:PULS:
WIDT command are preserved. Edge and pulse
width may be adjusted to supported levels.
Repetition rates will be approximated from the
frequency. For accurate repetition rates, the period
should be adjusted using the
SOURce[1|2]:PULS:PER command
SOUR[1|2]:APPLy:PULSe [<frequency> [,<amplitude>
[,<offset>] ]]
<frequency>
500μHz~25MHz
<amplitude>
1mVpp~10Vpp (50)
Vue de la page 202