Gw-instek AFG-2225 User Manual Manuel d'utilisateur Page 246

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 301
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 245
AFG-2225 Series User Manual
246
SOUR1:SWE:TIME?
+2.0000E+01
Returns the sweep time (20 seconds).
SOURce[1|2]:SWEep:SOURce
Source Specific
Command
Sets or queries the trigger source as immediate
(internal), external or manual. Immediate (internal)
is the default trigger source. IMMediate will
constantly output a swept waveform. EXTernal
will output a swept waveform after each external
trigger pulse. Manual will ouput a swept
waveform after the trigger softkey is pressed.
If the APPLy command was used to create the
waveform shape, the source is automatically set to
IMMediate.
The *OPC/*OPC? command/query can be used to
signal the end of the sweep.
SOURce[1|2]: SWEep:SOURce {IMMediate|EXTernal|
MANual}
SOUR1: SWE:SOUR EXT
Sets the sweep source to external.
SOURce[1|2]: SWEep:SOURce?
IMM
Immediate
EXT
External
MANual
Manual
SOUR1:SWE:SOUR?
IMM
The sweep source is set to immediate.