:SYSTem:CONFigure:BEEPer[:STATe]
Set
Query
Description
Syntax
Query Syntax
Parameter
OFF | 0
Turns the buzzer off.
ON | 1
Turns the buzzer on.
Return parameter
<bool>
Returns the buzzer status.
:SYSTem:CONFigure:BLEeder[:STATe]
Set
Query
Description
Syntax
Query Syntax
Parameter
OFF | 0
Turns the bleeder resistor off.
ON | 1
Turns the bleeder resistor on.
Return parameter
<bool>
Returns bleeder resistor status.
:SYSTem:CONFigure:CURRent:CONTrol
Set
Query
Description
Syntax
Query Syntax
Parameter/Return
<NR1>
Description
0
Local (Panel) control
1
External voltage control
2
External resistance control; 10kΩ = Io max,
0kΩ = Io min.