REMOTE CONTROL
89
External resistance control; 10kΩ = Io min,
0kΩ = Io max.
:SYSTem:CONFigure:VOLTage:CONTrol
Sets or queries the CV control mode (local control
(panel), external voltage control, external
resistance control). This setting is applied only
after the unit is reset.
:SYSTem:CONFigure:VOLTage:CONTrol { <NR1> }
:SYSTem:CONFigure:VOLTage:CONTrol?
External resistance control; 10kΩ = Io max,
0kΩ = Io min.
External resistance control; 10kΩ = Io min,
0kΩ = Io max.
:SYSTem:CONFigure:OUTPut:PON[:STATe]
Sets the output state at power-on. This is the
equivalent to the F-92 (Output Status when Power
ON) power on configuration settings.
:SYSTem:CONFigure:OUTPut:PON[:STATe]
{<NR1>|SAFE|FORCe |AUTO}
:SYSTem:CONFigure:OUTPut:PON[:STATe]?
The PSU turns on in the same state the unit
was in prior to the previous shut down. The
output is set to off (default).
The PSU turns on in the same state the unit
was in prior to the previous shut down. The
output is set to on.
The PSU turns on in the same state the unit
was in prior to the previous shut down, but
with the same output on/off setting.
The power on output setting is “SAFE”.
The power on output setting is “FORCe”.
The power on output setting is “AUTO”.