Gw-instek GDS-200 Series Programming Manual Manuel d'utilisateur Page 61

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 139
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 60
COMMAND DETAILS
61
Example
:MEASure:SOURce1 CH1
:MEASure:MAX?
1.90E-3
Selects Channel 1, and then measures the
maximum amplitude.
:MEASure:MIN
Description
Returns the minimum amplitude.
Syntax
:MEASure:MIN?
Related
Commands
:MEASure:SOURce<X>
Return parameter
<NR3>
Returns the minimum amplitude.
Chan Off
Indicates the source channel is not
activated.
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH1
:MEASure:MIN?
-8.00E-3
Selects Channel 1, and then measures the
minimum amplitude.
:MEASure:AMPlitude
Description
Returns the amplitude difference between the
Vhigh-Vlow.
Syntax
:MEASure:AMPlitude?
Related
Commands
:MEASure:SOURce<X>
Return parameter
<NR3>
Returns the amplitude.
Query
Query
Vue de la page 60
1 2 ... 56 57 58 59 60 61 62 63 64 65 66 ... 138 139

Commentaires sur ces manuels

Pas de commentaire