COMMAND DETAILS
95
:TIMebase:WINDow:SCALe
Description
Sets or queries the zoom horizontal scale.
Note
If the oscilloscope is underZOOM” mode, the
main timebase function will be disabled and
cannot be modified.
Syntax
:TIMebase:WINDow:SCALe {<NRf> | ?}
Related
commands
:TIMebase:MODe
Parameter
<NRf>
Zoom horizontal scale. The range will
depend on the time base.
Return parameter
<NR3>
Returns the zoom horizontal scale.
Example
:TIMebase:WINDow:SCALe 1.0E-3
Sets the zoom horizontal scale to 1ms.
:TIMebase:EXPand
Description
Sets or queries the horizontal expand mode.
Syntax
:TIMebase:EXPand { CENTer | TRIGger | ? }
Parameter
CENTer
Sets the horizontal expand mode by
center.
TRIGger
Sets the horizontal expand mode by
the trigger position.
Return parameter
Sets the horizontal expand mode (CENTER,
TRIGGER).
Example
:TIMebase:EXPand TRIGger
Sets the horizontal expansion from the trigger
position.
Set
Query
Set
Query