GDS-2000A Programming Manual
148
Related
commands
:TRIGger:LOGic:PATtern:WHEn
Parameter/Return
parameter
<NR3>
Pattern trigger delta time in seconds.
(10nS to 10S)
Example
:TRIGger:LOGic:PATtern:DELTatime?
8.960e-05
:TRIGger:LOGic:PATtern:WHEn
Description
Sets or returns the pattern logic condition on
which to trigger the oscilloscope.
Syntax
:TRIGger:LOGic:PATtern:WHEn { TRUE | FALSE |
LESSthan | MOREthan | Equal | UNEQual | ? }
Related
commands
:TRIGger:LOGic:PATtern:DELTatime
Parameter/
Return parameter
TRUE
Set true mode.
FALSE
Set false mode.
LESSTHAN
Set less than mode
Is True < time period*
*Set from
:TRIGger:LOGic:PATtern:DELTatime
MORETHAN
Set more than mode
Is True > time period*
*Set from
:TRIGger:LOGic:PATtern:DELTatime
EQUAL
Set less than mode
Is True = time period*
*Set from
TRIGger:LOGic:PATtern:DELTatime
UNEQUAL
Set less than mode
Is True ≠ time period*
*Set from
TRIGger:LOGic:PATtern:DELTatime