Gw-instek GDS-2000A series Programming Manual Manuel d'utilisateur Page 171

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 272
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 170
COMMAND DETAILS
171
Related
commands
:BUS1:STATE
Parameter/Return
parameter
UART
Sets the bus to UART mode.
I2C
Sets the bus to I
2
C mode.
SPI
Sets the bus to SPI mode.
PARallel
Sets the bus to parallel mode.
Example
:BUS1:TYPe SPI
Sets the bus to SPI mode.
:BUS1:I2C:ADDRess:RWINClude
Description
Sets or queries whether the read/write bit is
included in the I
2
C address.
Syntax
:BUS1:I2C:ADDRess:RWINClude { OFF | ON | ? }
Related
commands
:BUS1:STATE
Parameter
OFF
The R/W is not included.
ON
The R/W is included.
Return parameter
0
The R/W is not included.
1
The R/W is included.
Example
:BUS1:I2C:ADDRess:RWINClude ON
Includes the R/W bit in the I
2
C address.
:BUS1:I2C:SCLK:SOURce
Description
Sets or queries which channel is used for the I
2
C
SCLK source.
Syntax
:BUS1:I2C:SCLK:SOURce { D0 | D1 | D2 | D3 | D4 | D5
| D6 | D7 | D8 | D9 | D10 | D11 | D12 | D13 | D14 | D15
| ? }
Parameter/Return
parameter
D0 to D15
Digital channels D0 to D15
Set
Query
Set
Query
Vue de la page 170
1 2 ... 166 167 168 169 170 171 172 173 174 175 176 ... 271 272

Commentaires sur ces manuels

Pas de commentaire