Gw-instek GDS-3000 Series Programming Manual Manuel d'utilisateur Page 60

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 103
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 59
GDS-3000 Programming Manual
60
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce CH1
:MEASure:FALL?
Selects Channel 1, and then measures the fall time.
:MEASure:FOVShoot
Query
Description
Returns the fall overshoot amplitude.
Syntax
:MEASure:FOVShoot{?}
Return parameter
Returns the fall overshoot as a percentage, <NR3>
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH1
:MEASure:FOVShoot?
1.27E+0
Selects Channel 1, and then measures the fall
overshoot.
:MEASure:FPReshoot
Query
Description
Returns fall preshoot amplitude.
Syntax
:MEASure:FPReshoot{?}
Returns
Returns the fall preshoot as <NR3>.
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH1
:MEASure:FPReshoot?
Selects Channel 1, and then measures the fall
preshoot.