COMMAND DETAILS
83
Parameter
OFF
Frequency rejection off.
HF
High frequency filter on
LF
Low frequency filter on
Return parameter
Returns the status of the frequency filter.
Example
:TRIGger:REJect OFF
Turns the frequency filter off.
:TRIGger:MODe
Set
Query
Description
Sets or queries the trigger mode.
Syntax
:TRIGger:MODe {AUTo | NORMal | ?}
Parameter
AUTo
Auto trigger (Untriggered roll)
NORMal
Normal trigger
Return parameter
Returns the trigger mode.
Example
:TRIGger:MODe NORMal
Sets the trigger mode to normal.
:TRIGger:HOLDoff
Set
Query
Description
Sets or queries the holdoff time.
Syntax
:TRIGger:HOLDoff {<NRf> | ?}
Parameter
<NRf>
Holdoff time
Return parameter
Returns the trigger holdoff time as <NR3>.
Example
:TRIGger:HOLDoff 1.00E-8
Sets the trigger holdoff time to 10ns.
:TRIGger:HLEVel
Set
Query
Description
Sets or queries the high trigger level (applicable for
Rise and Fall/Pulse Runt trigger).