Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH 1
:MEASure:PDUTy?
5.000E+01
Selects Channel 1, and then measures the positive
duty cycle.
:MEASure:PERiod
Query
Description
Returns the period.
Syntax
:MEASure:PERiod{?}
Return parameter
Returns the period as <NR3>
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH 1
:MEASure:PERiod?
1.0E-3
Selects Channel 1, and then measures the period.
:MEASure:PWIDth
Query
Description
Returns the first positive pulse width.
Syntax
:MEASure:PWIDth{?}
Return parameter
Returns the first positive pulse width as <NR3>
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH 1
:MEASure:PWIDth?
5.0E-6
Selects Channel 1, and then measures the positive
pulse width.