GSP-930 Programming Manual
136
:FREQ:CENT:STEP:AUTO OFF
[:SENSe]:FREQuency:OFFSet
Set
Query
Sets or queries the frequency offset settings.
[:SENSe]:FREQuency:OFFSet <freq>
[:SENSe]:FREQuency:OFFSet?
<freq>
<NRf>
<NR3>
FREQ:OFFS: 1.0e+6
[:SENSe]:FREQuency:SPAN
Set
Query
Sets or queries the span settings.
[:SENSe]:FREQuency:SPAN <freq>
[:SENSe]:FREQuency:SPAN?
<freq>
<NRf>
<NR3>
Hz
FREQ:SPAN: 2.0e+9
[:SENSe]:FREQuency:SPAN:FULL
Set
Set the span to Full Span.
[:SENSe]:FREQuency:SPAN:FULL
:FREQ:SPAN:FULL
[:SENSe]:FREQuency:SPAN:PREVious
Set
Set the span to the previous span setting.
[:SENSe]:FREQuency:SPAN:PREVious
:FREQ:SPAN:PREV