GSP-930 Programming Manual
68
:CALCulate:CNR:STATe?
0
CNR is off.
1
CNR is on.
OFF
CNR is off.
ON
CNR is on.
0
CNR is off.
1
CNR is on.
:CALC:CNR:STAT?
>1
:CALCulate:CSO:RESult?
Query
Returns the CSO measurement result in dB.
:CALCulate:CSO:RESult?
<NR3>
CSO measurement in dB
:CALC:CSO:RES?
>4.04e+00
:CALCulate:CSO:STATe
Set
Query
Sets or queries the state of the CSO measurement
function.
:CALCulate:CSO:STATe {ON|OFF|1|0}
:CALCulate:CSO:STATe?
0
CSO is off.
1
CSO is on.
OFF
CSO is off.
ON
CSO is on.
0
CSO is off.
1
CSO is on.
:CALC:CSO:STAT?
>1