9.1 Output
APS-1102 Programmable AC/DC Power Source 9-3
Output terminals
Terminal block with M4 screws (rear panel)
AC receptacle (universal type, front panel)
Note: Use AC receptacle for AC (0 V AC to 250 V AC). When DC is included, use screw terminal
block on rear panel.
Rated output
100 V range: 100 Vrms (AC) / 100 V (DC)
200 V range: 200 Vrms (AC) / 200 V (DC)
Output voltage settings
(When signal source mode is internal mode or internal + external mode, no load)
Note: The AC settings (peak value)+ DC setting that can be set are within the voltage setting limit
range.
AC
100 V range: 0.0 to 140.0 Vrms
200 V range: 0.0 to 280.0 Vrms
Setting resolution: 0.1 Vrms
Setting accuracy: ±(0.5% of set value +0.6 Vrms): 100 V range
±(0.5% of set value +1.2 Vrms): 200 V range
(AC mode, 50 Hz, 23 ±5°C)
DC
100 V range: 200.0 V to +200.0 V
200 V range: 400.0 V to +400.0 V
Setting resolution: 0.1 V
Setting accuracy: ±( 0.5 % of set value + 0.8 V): 100 V range
±( 0.5 % of set value + 1.6 V): 200 V range
(AC+DC mode, 0 V AC setting, 23 ±5°C)
Maximum output current
100 V range: 10 Arms (AC) / 10 A (DC)
200 V range: 5 Arms (AC) / 5 A (DC)
Note 1: For the AC 100 V input system, the limit on the maximum output power may cause a
reduction in the maximum output current.
Note 2: At or above the rated output voltage, the limit on the maximum output power reduces the
maximum output current.
Note 3: When output frequency is 40 Hz or lower, or it is 400 Hz or higher, the maximum output
current may decrease.
Note 4: The RMS value for AC + DC is within the maximum output current.