Precision LCR Meter
LCR-800
USER MANUAL
GW INSTEK PART NO. 82CR-81900MK1
ISO-9001 CERTIFIED MANUFACTURER
This manual contains proprietary information, which is protected by
copyright. All rights are reserved. No part of this manual may be
photocopied, reproduced or translated to another language without
prior written consent of the Good Will Instrument company.
The information in this manual was correct at the time of printing.
However, Good Will continues to improve products and reserves the
right to change specifications, equipment, and maintenance
procedures at any time without notice.
Good Will Instrument Co., Ltd.
No. 7-1, Jhongsing Rd., Tucheng City, Taipei County 236, Taiwan.
Vue de la page 0
1 2 3 4 5 6 ... 71 72

Résumé du contenu

Page 1 - Precision LCR Meter

Precision LCR Meter LCR-800 USER MANUAL GW INSTEK PART NO. 82CR-81900MK1 ISO-9001 CERTIFIED MANUFACTURER This manual contains proprietary info

Page 2 - Table of Contents

GETTING STARTED 19 Counter- clockwise: bright Clockwise: dark LCR-800 User Manual 20 Fixture Connection Fixture structure Background Th

Page 3 - SAFETY INSTRUCTIONS

GETTING STARTED 21 Fixture connection Panel operation 1. Discharge the test component before connecting the fixture set. 2. Connect the Kelvin

Page 4

GETTING STARTED 23 +PowerSupply200mA MAXMAX30VCATEXTERNAL BIAS+LCDDon’t connect LCR-800 User Manual 24 Zeroing Zeroing calibration Backgro

Page 5 - GETTING STARTED

GETTING STARTED 25 Warning If the test failed, ensure your cables or test fixtures are open and not shorted. Ensure R.H is OFF. After inspection t

Page 6 - Measurement Types

GETTING STARTED 27 General Capacitors Capacitors are usually measured in series except for extremely small capacitance. Like with inductors, large

Page 7 - Front Panel Overview

BASIC MEASUREMENT 29 BASIC MEASUREMENT Basic Measurement details how to measure individual components and how to configure the LCR-800 settings. B

Page 8 - Rear Panel Overview

BASIC MEASUREMENT 31 Parameter Configuration Measurement Speed Measurement Speed The LCR-800 series support 3 different measurement speeds: slow,

Page 9 - Power Up

BASIC MEASUREMENT 33 Measurement Modes Measurement mode The LCR-800 has a number of different measurement modes. Primary and secondary measuremen

Page 10 - Fixture Connection

BASIC MEASUREMENT 35 Panel operation 1. Press the 7/Bias key on the number pad to cycle from internal to external bias. The bottom of the screen wi

Page 11 - Fixture connection

BASIC MEASUREMENT 37 1.1kHz The nearest frequency will be selected from the 504(LCR-281) nominal frequencies, and updated in the display. Here,

Page 12 - Zeroing

SAFETY INSTRUCTIONS 3 Table of Contents SAFETY INSTRUCTIONS ... 5GETTING STARTED ...

Page 13

BASIC MEASUREMENT 39 PPM will be displayed on the right hand side of the screen, next to mode. Set constant voltage source Background If a D

Page 14

BASIC MEASUREMENT 41 The average of 10 tests The number of averages is displayed in the main panel and in the AVGE menu icon after a shor

Page 15 - BASIC MEASUREMENT

BASIC MEASUREMENT 43 Running Measurement Select Single measurement Background Measurements can be manually controlled (MANU) or automatically updat

Page 16 - Parameter Configuration

BASIC MEASUREMENT 45 Store Recall Store or Recall Memory Settings Background The LCR-800 series have 100 blocks of memory available for saving set

Page 17 - Set Bias voltage

47 2. Press 1 to recall the calibration settings or 2 to cancel. OR 3. When the status bar has completed, the calibration settings are reca

Page 18 - Set measurement frequency

BIN FUNCTIONS 49 Bin Summary Menu Bin Summary Menu Overview ... 68Bin Summary/Results ...

Page 19 - Set PPM for D/Q measurements

BIN FUNCTIONS 51 Parameter 1,2,3,4 Delay Delay between each measurement Parameter 0~99999 ms MANU/ AUTO Selects between automatic and manual

Page 20 - Set Average

BIN FUNCTIONS 53 Circuit Setting Background Use Circuit setting to change the equivalent circuit. Panel Operation 1. Use the arrow menu keys (F1/

Page 21 - Set Nominal Values

BIN FUNCTIONS 55 Select/Run Auto/Manu Sorting Background Set the test mode from manual to automatic. Panel operation 1. Hold the START key for a

Page 22 - Running Measurement

BIN FUNCTIONS 57 Bias Setting Background Set internal or external bias voltage. Panel Operation 1. Use the arrow menu keys (F1/F2) to move the cu

Page 23 - Store Recall

SAFETY INSTRUCTIONS 5 SAFETY INSTRUCTIONS This chapter contains important safety instructions that you must follow when operating or storing the LCR

Page 24 - BIN FUNCTIONS

BIN FUNCTIONS 59 2. Press ON (F3) to turn constant voltage on. 3. Press OFF (F4) to turn constant voltage off. Delay Setting Background The

Page 25 - Binning Menu

BIN FUNCTIONS 61 Set Bin Menu Set Bin Menu Overview Bin number Displays the current bin. Bin Settings Configures the nominal value, nominal uni

Page 26 - Mode Setting

BIN FUNCTIONS 63 2. Use the arrow menu keys (F1/F2) to move the cursor to SET BIN. 4. Press SET (F3). 5. The Bin menu appears. ΩΩ+ :

Page 27 - Frequency Setting

BIN FUNCTIONS 65 For example: 20 Ω. Set Max/Min Absolute Limit Background The maximum and minimum absolute limits of the current bin can be set.

Page 28 - Voltage Setting

BIN FUNCTIONS 67 Clear Bins Background All the bin settings can be cleared for all the bins. Panel operation 1. Press NEXT BIN until BIN1 is t

Page 29 - Constant Voltage Setting

BIN FUNCTIONS 69 PHI Indicates that a test result is greater than the maximum limit. PHI= Primary Hi PLO Indicates that a test result is les

Page 30 - Average Setting

BIN FUNCTIONS 71 5. To clear the test results, press CLR followed by F3 (YES->) to confirm. 6. Press EXIT to exit the bin summary results.

Page 31 - Set Bin Menu

RS232 REMOTE 73 LCR Setup RS232 Settings Background RS232 must first be enabled on the LCR-800 before trying to connect with a PC. Panel operati

Page 32 - Ω- : 4.02%

RS232 REMOTE 75 Message Area The message area displays the current status of connection, results, files saved and restored. Message Display Key T

Page 33 - Set Max/Min Percentage Limit

RS232 REMOTE 77 Note DataBits, StopBits, Parity and Flowcontrol cannot be edited. Note All file menus (File, Option, Data, Help) are restricted i

Page 34 - Bin Summary Menu

SAFETY INSTRUCTIONS 7  To ensure fire protection, replace the fuse only with the specified type and rating.  Disconnect the power cord before f

Page 35 - Bin Summary/Results

RS232 REMOTE 79 File Settings 3. Choose a drive and directory from the drop down selections. 4. Type a file name identifier in the File_Name pa

Page 36 - RS232 REMOTE

RS232 REMOTE 81 6. To exit LCR Viewer, press the POWER button or go to the File Exit menu. 7. To turn the message area on or off press the Me

Page 37 - LCR Viewer

RS232 REMOTE 83 4. Press OK to exit. Note All file menus (File, Option, Data, Help) are restricted in Auto mode. To change to manual mode see

Page 38

RS232 REMOTE 85 6. Connect to the terminal program with the following configuration settings:  COM port (as per PC)  Baud rate- 38400  Data

Page 39 - LCR Viewer File Settings

PROGRAMMING 87 PROGRAMMING Command overview lists all the LCR-800 commands and command queries. The command syntax section shows you the basic rul

Page 40

PROGRAMMING 89 Output -1.0000 -1.0000 2D 31 2E 30 30 30 35 As can be seen above, positive input numbers use the ASCII “+” whilst the output will

Page 41 - View Help

PROGRAMMING 91 SPEED Command/Query The speed command sets the measurement speed of the instrument. The faster the measurement speed the lower th

Page 42 - Terminal Connection

PROGRAMMING 93 Example MAIN:MODE:RQ<^END^M> Sets the mode to R/Q (Resistance/Quality factor) Query Syntax MAIN:MODE?<^END^M>or<^

Page 43

PROGRAMMING 95 0.005~1.275 (5 characters, including a decimal) 5mV~1.275 Example MAIN:VOLT 0.005<^END^M> Sets the test signal voltage to 5

Page 44 - PROGRAMMING

PROGRAMMING 97 C.V Command/Query Turns Constant Voltage on or off. Queries the constant voltage status. Syntax MAIN:C.V.:<string> <^END^

Page 45 - Commands

SAFETY INSTRUCTIONS 9 Power cord for the United Kingdom When using the LCR-800 in the United Kingdom, make sure the power cord meets the following s

Page 46 - DISPLAY

PROGRAMMING 99 Example MAIN:EXTB:OFF.<^END^M> Turn External Bias off. Query Syntax MAIN:EXTB?<^END^M>or<^J^M> Return String &l

Page 47 - VOLTAGE

PROGRAMMING 101 Parameter < variable > Nominal Value -XXXXXXX ~ +XXXXXXX Must be any 8 digit character including a decimal place and signa

Page 48 - RANGE HOLD

PROGRAMMING 103 AVERAGE Command/Query Sets the average number from 1~255. The average number indicates how many test samples are used to create an

Page 49

PROGRAMMING 105 COMU:MONO:819.<^END> LCR-819 COMU:MONO:821.<^END> LCR-821 Query Example COMU:MONO<^END^M> COMU:MONO:816.<^END&

Page 50 - NOM.VAL

PROGRAMMING 107 <value> Test result Any 7 digit ASCII including sp (+) or – characters and a decimal point. Primary measurement value Example

Page 51

PROGRAMMING 109 SECONDARY FACTOR, PRIMARY UNIT, SECONDARY UNIT Measurement Secondary measurement result is returned along with the primary unit a

Page 52 - MODEL NUMBER

INTERACE 111 INTERACE This chapter describes basic interface aspects of the RS-232 and Handler interfaces. RS232 Interface Configuration Configu

Page 53 - PRIMARY FACTOR

INTERACE 113 Connection PC LCR Meter DB9 Pin Signal Signal DB9 Pin 2 RxD TxD 3 3 TxD RxD 2 4 DTR DSR, DCD 6,1 5 GND GND 5 6,1 DSR, DCD DTR 4 7

Page 54 - PRIMARY OVER SECONDARY OVER

INTERACE 115 Pin11 /O_BIN_11 Go, Assigned BIN 11 Pin12 /O_BIN_12 Go, Assigned BIN 12 Pin13 /O_BIN_13 Go, Assigned BIN 13 Pin14 /O_S_OVER No

Page 55

INTERACE 117 /O_S_REJ /O_S_OVER The /O_S_REJ or /O_S_OVER signal will go low when the secondary measurement is over D_Max or under D_Min, whilst i

Page 56 - INTERACE

GETTING STARTED 11 Main Features Performance  12Hz ~ 200kHz wide test frequency (LCR-821)  5 digit measurement resolution  2V DC bias voltag

Page 57

INTERACE 119 Handler Timing Background The handler timing characteristics are described in the timing diagram. Times T1 to T6 are described in the

Page 58 - Signal Overview

FAQ 121 FAQ Q1. What is the correct procedure for Open/Short Zeroing when using the LCR-06A test fixture? A1. The LCR-06A test fixture is very sen

Page 59

APPENDIX 123 APPENDIX Fuse Replacement Step 1. Disconnect the power cord and then remove the fuse socket using a flat screwdriver. 2. Replac

Page 60 - Handler Timing

APPENDIX 125 Resistance (R) Series diagram Parallel diagram Series formula 21 QRRPS Q=quality factor Parallel formula 21 QRRSP Q=quali

Page 61

APPENDIX 127 Capacitance (C) Formula Background Capacitance measures the amount of electronic charge stored between two terminals. Type  Series

Page 62 - APPENDIX

APPENDIX 129 Impedance (Z) and Admittance (Y = 1/Z) Formula Background Impedance measures the total amount of opposition between two terminals in

Page 63 -  Parallel Conductance

APPENDIX 131 Angle (θ) Formula Background The Angle (θ) measures the phase on which Impedance (Z), Admittance (Y), Quality factor (Q), and Dissipa

Page 64 - Inductance (L) Formula

APPENDIX 133 R(L/R) Q≦1 2counts + 0.02%[(1+Ka)* or (Rx/Rmax)* or (Rmin/Rx)*] (1+ | Q│)(1+Kb+Kc)+0.03% Q≧1 2counts + 0.02%[(1+Ka)** or (Lx/Lmax)**

Page 65

APPENDIX 135 Table3 Y Range constant- Range Hold Component Inductor Capacitor Resistor Range Max Min Max Min Max Min Range1 16mH/f

Page 66 - Accuracy Definitions

APPENDIX 137 Dissipation factor (D)+ in ppm 1 ppm ~ 9999 ppm Quality factor (Q)** in ppm 1 ppm ~ 9999 ppm DELTA % 0.00001% ~ 99999% *s=seri

Page 67

GETTING STARTED 13 Front Panel Overview LCD Display 240 by 128, dot matrix LCD display. Function keys Assigned to the menu on the right side of

Page 68 - Specifications

APPENDIX 139 Power Source Line Voltage 100V~240V AC, 50~60Hz/ 400Hz Power Consumption 45 Watts maximum Fuse Slow-blow 5X20 mm, 3A/250V UL/CS

Page 69

INDEX 141 INDEX Absolute limit settings set bin menu ... 65 Admittance overview ... 129 Angle o

Page 70 - EC Declaration of Conformity

INDEX 143 wire capacitance ... 27 Memory specification ... 138 Mode settings handler menu ...

Page 71 - LCR-800 User Manual

GETTING STARTED 15 Start The Start key is used to start measuring when in manual mode. The start key can also be used to select automatic or manua

Page 72

GETTING STARTED 17 Fuse / Power Socket The fuse holder contains the main fuse, 5TT 3A/250V. For fuse replacement details, see page 123. The mains