Gw-instek APS-1102 User Manual Manuel d'utilisateur Page 97

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 265
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 96
4.4 Using the Sequence Function
APS-1102 Programmable AC/DC Power Source 4-33
Table 4-10. Setting Items in PROGRAM Screen (3/3)
Setting Name Item Operation
STEP TERM Step end
Sets operation after end of step.
Select one of the following three options.
CONT: Sequence continuation
STOP: Change to Idle mode
HOLD: Change to Hold mode
JUMP STEP Jump step
Sets the step number to jump to after the end of the
previous step.
0: Continue to next step number
1 to 255: Jump to specified step number
JUMP NUM Jump times
Sets the number of times to execute the jump operation
specified by JUMP STEP.
0: Unlimited jumps
1 to 999: Specified number of jumps
BRANCH0 Branch step 0
Sets the step number to jump to when trigger input has
occurred.
Two types of branch steps can be set: BRANCH0 and
BRANCH1.
[Command example]
When a STOP is set after a small number of sweeps at the
jump destination step, it enables uses where there is a
safe region for saving data if necessary.
0: Branch disabled
1 to 255: Jump to specified step number
BRANCH1 Branch step 1
The operation steps for each of the setting items in the PROGRAM screen are described below.
Operation step <1>
The settings for step number (STEP), step time (TIME), DC voltage (DC VOLT, AC+DC mode only),
AC voltage (AC VOLT), AC frequency (FREQ), phase (PHS), step end phase (STOP PHS), jump step
(JUMP STEP), jump times (JUMP NUM), and branch (BRANCH0/BRANCH1) are made by entering
numerical values for various items in the order described below.
The example described below is when entering the setting for step time (TIME).
Vue de la page 96
1 2 ... 92 93 94 95 96 97 98 99 100 101 102 ... 264 265

Commentaires sur ces manuels

Pas de commentaire