3.4 Main Operation Example
APS-1102 Programmable AC/DC Power Source 3-17
3.4.2 Setting output mode
The APS-1102 provides the eight output modes listed in Table 3-4. The output mode cannot be changed
while output is on. Before changing the output mode, set output to off.
Table 3-4. Output Mode List
Operation
Mode
Signal Source Mode Output Mode Reference
AC
INT
(internal)
AC-INT
“3.4.2 Setting output mode”
EXT
(external)
AC-EXT
“4.5 Control Using External Control I/O
Connector
”
ADD
(internal + external)
AC-ADD
“4.10 Adding External Signals and
Internal Signals
SYNC
(external sync)
AC-SYNC
“4.7 Synchronization of Output to
External Signal
”
AC+DC
INT
(internal)
AC+DC-INT
“4.1 Use as a DC Power Source”
EXT
(external)
AC+DC-EXT
“4.5 Control Using External Control I/O
Connector
”
ADD
(internal + external)
AC+DC-ADD
“4.10 Adding External Signals and
Internal Signals
SYNC
(external sync)
AC+DC-SYNC
“4.7 Synchronization of Output to
External Signal”
Setting to AC-INT mode is described below as an example.
Commentaires sur ces manuels