Example
:RES:STAT:LOW:RISE 0.1
Sets the rising slew rate
to 0.1A/uS.
Query Syntax
:RESistance:STATic:LOW:RISE/FALL? [MIN|MAX]
Return Parameter
<NR2> [MAX|MIN]
Slew rate
1 Unit =1 amp/uS
Returns the slew rate.
MAX, MIN
Returns the allowable
maximum and minimum.
Query Example
:RES:STAT:LOW:RISE?
MAX
0.8000
For low range CR mode,
the maximum value for
the rising slew rate is 0.8
A/uS for the specific
channel.
:RESistance:STATic:HIGH:AVALue/BVALue
Channel Specific
Command
Description
Sets the high range A/B Value for constant
resistance static mode.
Syntax
:RESistance:STATic:HIGH:AVALue/BVALue
<NRf+>[OHM]
Parameter
NRf+[OHM]
AVALue 10
Sets A Value to 10 ohms.
(high range only)
BVALue 20OHM
Sets B Value to 20 ohms.
(high Range only)
AVALue MIN
Sets A Value to the
minimum level for the
specific channel.
AVALue MAX
Sets A Value to the
maximum level for the
specific channel.
Example
:RES:STAT:HIGH:BVAL 10
Sets high range CR static
mode B Value to 10
ohms.