Gw-instek PEL-2000 Series Programming User Manual Manuel d'utilisateur Page 152

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 170
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 151
PEL-2000 Programming Manual
152
1.2
1.2A/us
1.2 A/us
1.2A/us
MAX/MIN
Maximum or minimum
value.
Example
:SEQ:POIN:RISE .3 A
Sets the rising slew rate
to 0.3 A/us
:SEQ:POIN:FALL .4 A
Sets the falling slew rate
to 0.4 A/us
Query Syntax
:SEQuence:POINt::RISE/FALL? [MAX|MIN]
Return Parameter
<NR1>
Slew Rate
1 unit = 1 A/us
Returns the slew rate.
MAX/MIN
Returns the allowable
maximum and minimum.
Query Example
:SEQ:POIN:RISE?
0.30000
Returns the rising slew
rate (0.3 A/us).
:SEQ:POIN:FALL?
0.40000
Returns the falling slew
rate (0.4 A/us).
:SEQuence:POINt:TIME
Channel Specific
Command
Description
Sets the duration time of the current point in
seconds.
Syntax
:SEQuence:POINt:TIME <NRf>[S]|MIN|MAX
Parameter
<NRf>
Duration Time
0.0001~60000
0.0001~60,000.0 seconds
0.0001~60000S
0.0001~60,000.0 seconds
MIN
0.0001seconds
MAX
60,000 seconds
Example
:SEQ:POIN:TIME 10
Sets the point duration
time to 10 seconds.
Query Syntax
:SEQuence:POIN:TIME? [MAX|MIN]