48
:CONFigure:PROTection:UVP:LEVel
Channel Specific
Command
Description
Sets the under voltage protection level for the
current/specific channel. The level can be set to
any applicable level or to the channel
maximum/minimum.
Syntax
:CONFigure:PROTection:UVP:LEVel
<NRf>[W]|MIN|MAX
Parameter
<NRf>
UVP Level
20
20 Volts
20V
20 Volts
MIN
Sets to the minimum level
(OFF)
MAX
Sets the voltage limit to
the maximum level
Example
:CONF:PROT:UVP:LEV MIN
Sets the UVP limit to OFF
Query Syntax
:CONFigure:PROTection:UVP:LEVel? [MIN|MAX]
Return Parameter
<NRf>
Power protection level
1 unit = 1 volt
Returns the UVP level as
volts.
MAX/MIN
Returns the allowable
maximum and minimum.
Query Example
:CONF:PROT:UVP:LEV?
75
UVP level is at 75 volts.