COMMAND DETAILS
93
1
OCP test active
Query Example
:OCP:STAT?
0
The test has ended.
:OCP:SAVE
Channel Specific
Command
Description
Saves the current COP Test Automation
parameters.
Syntax
:OCP:SAVE
:OCP:RESult?
Query
Description
Returns the OCP Test Automation results.
Query Syntax
:OCP:RESult?
Query Example
:OCP:RES?
Ch1 OCP Voltage, Ch1
OCP Current, Ch2 OCP
Voltage, Ch2 OCP Current,
Ch3 OCP Voltage, Ch3
OCP Current, Ch4 OCP
Voltage, Ch4 OCP Current,
Ch5 OCP Voltage, Ch5
OCP Current, Ch6 OCP
Voltage, Ch6 OCP Current,
Ch7 OCP Voltage, Ch7
OCP Current, Ch8 OCP
Voltage, Ch8 OCP Current
This is an example of the
results that are returned
for the PEL-2004.
:OCP:RUN
Command
Description
Turns the OCP Test Automation function on or off.
Syntax
:OCP:RUN { 0 | OFF| 1 | ON }
Parameter
0/OFF
Turn off.
1/ON
Turn on.
Example
:OCP:RUN OFF
Turn the test off.