COMMAND DETAILS
125
Query Syntax
:STATus:CHANnel:NTRansition/PTRansition? <NR1>
Return Parameter
<NR1>
Event
<NR1>
Event
1
OC
16
OT
2
OV
32
G/N
4
OP
64
UVP
8
RV
128~65535
Not Used
Query Example
:STAT:CHAN:NTR?
4
OP is set as a negative
transition.
:STATus:CSUMmary:ENABle
Channel Specific
Command
Description
Determines which channels in the Channel
Summary Register group can set the CSUM bit of
the Status Byte Register. The mask values are the
bit weights of each corresponding channel in the
Channel Summary Enable Register. See page 165
for details.
Syntax
:STATus:CSUMmary:ENABle <NR1>
Parameter
<NR1>
Event
<NR1>
Event
1
CH1
16
CH5
2
CH2
32
CH6
4
CH3
64
CH7
8
CH4
128
CH8
Example
:STAT:CSUM: 3
Events from channel 1
and 2 are enabled
Query Syntax
:STATus:CSUMmary:ENABle? <NR1>
Return Parameter
<NR1>
Event
<NR1>
Event
1
CH1
16
CH5
2
CH2
32
CH6
4
CH3
64
CH7
8
CH4
128
CH8
Vue de la page 124