COMMAND DETAILS
59
:CURRent:STATic:LOW:AVALue/BVALue
Channel Specific
Command
Description
Sets the low range A/B Value for constant current
static mode.
Syntax
:CURRent:STATic:LOW:AVALue/BVALue <NRf+>[A]
Parameter
NRf+[A]
AVALue 1
Sets A Value to 1 Amp.
(Low range only)
BVALue 2
Sets B Value to 2 Amps.
(Low Range only)
AVALue 1A
Sets A Value to 1 Amp.
(Low range only)
AVALue MIN
Sets A Value to the
minimum level for the
specific channel.
AVALue MAX
Sets A Value to the
maximum Level for the
specific channel.
Example
:CURR:STAT:LOW:AVAL 1
Sets low range CC static
mode A Value to 1 amp.
Query Syntax
:CURRent:STATic:LOW:AVALue/BVALue? [MAX|MIN]
Return Parameter
<NR2> [MAX|MIN]
Current
1 unit = 1 amp
Returns the current of the
A or B Value.
MAX/MIN
Returns the allowable
maximum and minimum.
Query Example
:CURR:STAT:LOW:BVAL?
MAX
2
Returns the maximum
current allowed for the
channel. (PEL-2020)