Gw-instek PEL-2000 Series Programming User Manual Manuel d'utilisateur Page 136

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 170
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 135
PEL-2000 Programming Manual
136
1 unit = 1 watt
Returns the power of the A
Value (L1) or B Value (L2).
MAX/MIN
Returns the allowable
maximum and minimum.
Query Example
:POW:L2? MAX
357.000
Returns the maximum
power allowed for the
channel. (PEL-2040)
:POWer:CURRent
Channel Specific
Command
Description
Sets the current limit for constant power mode.
The command is range dependant. If the current
range is Low, then the command will only apply to
the low range settings.
Syntax
:POWer:CURRent <NRf+>[A]
Parameter
<NRf+>[A]
1
Sets the current limit to
1A.
1A
Sets the current limit to
1A.
MIN
Sets the current limit to
the minimum level for the
specific channel.
MAX
Sets the current limit to
the maximum level for the
specific channel.
Example
:POW:CURR 1
Sets the current limit to
1A.
Query Syntax
:POW:CURRent? [MAX|MIN]
Return Parameter
<NR2> [MAX|MIN]
Current
1 unit = 1 amp
Returns the current limit.
MAX/MIN
Returns the allowable
maximum and minimum.
Vue de la page 135