Gw-instek PEL-2000 Series Programming User Manual Manuel d'utilisateur Page 156

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 170
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 155
PEL-2000 Programming Manual
156
Query Syntax
:SEQuence:CHANnel:TIME?
Return Parameter
<NR1>
Point
1~max channels
Returns the channel
duration time that the
specific channel is using.
Query Example
:SEQ:CHAN:TIME?
2
The specific channel is
using the channel
duration setting of
channel 2.
:SEQuence:RUN
Channel Specific
Command
Description
Turns the sequence On/Off.
Syntax
:SEQuence:RUN {OFF|0|ON|1}
Parameter
OFF/0
Off
ON/1
On
Example
:SEQ:RUN ON
Run the sequence.
:SEQuence:SAVE
Channel Specific
Command
Description
Saves the sequence for the specific channel.
Syntax
:SEQuence:SAVE
Example
:SEQ:SAVE
Saves the sequence.
:SEQuence:TRIGger:IN
Channel Specific
Command
Description
Turns the trigger input on/off for sequences. See
the :SEQuence:TRIGger:IN:CHANnel command to
set which channels this command applies to.
Syntax
:SEQuence:TRIGger:IN {OFF|0|ON|1}
Parameter
OFF/0
Off
ON/1
On