COMMAND DETAILS
131
Returns the allowable
maximum and minimum.
:VOLT:L1?
5
:VOLT:L1? MAX
81.6000
A Value is set to 5 volts.
Returns the maximum
settable voltage.
Sets or queries whether A Value or B Value is the
currently active value in CV mode.
:VOLTage:RECall {A|0|B|1}
Makes B Value the active
value.
Sets the voltage of A Value or B Value in CV mode.
:VOLTage:AVALue/BVALue <NRf+>[V]
Sets the voltage to the
minimum value for the
channel