COMMAND DETAILS
65
Query Example
:CURR:DYN:LOW:T1?
2.5
:CURR:DYN:LOW:T1?
MIN
0.000025
Returns the T1 time of
2.5 seconds.
Returns the minimum T1
time allowable for the
specific channel and
range.
:CURRent:DYNamic:LOW:L1/L2
Channel Specific
Command
Description
Sets the low range current levels (Level 1 & 2) for
CC dynamic mode.
Syntax
:CURRent:DYNamic:LOW:L1/L2 <NRf+>[A]
Parameter
NRf+[A]
Current
L1 1
Sets L1 to 1 Amp. (low
range only)
L2 2
Sets L2 to 2 Amps. (low
Range only)
L2 2A
Sets L2 to 2 Amps. (low
Range only)
L1/L2 MIN
Sets L1 or L2 to the
minimum level for the
specific channel.
L1/L2 MAX
Sets L1 or L2 to the
maximum Level for the
specific channel.
Example
:CURR:DYN:LOW:L1 10
In low range CC dynamic,
Set L1 (level 1) to 10
amps.
Query Syntax
:CURRent:DYNamic:LOW:L1/L2? [MIN|MAX]
Return Parameter
<NR2> [MAX|MIN]
Current
1 unit= 1 amp
Returns the current of
L1/L2, or the maximum or
minimum current allowed.
Vue de la page 64