MODE Subsystem
:MODE ............................................................................. 85
:MODE
Channel Specific
Command
Description
This command sets the operating mode of the
specific channel. Some modes are load module
dependant.
Syntax
:MODE {CCL|CCH|CCDL|CCDH|CRL|CRH|CRDL|
CRDH|CV|CPL|CPH|CVL|CVH}
Parameter
CCL
CC static mode, low range
CCH
CC static mode, high range
CCDL
CC dynamic mode, low range
CCDH
CC dynamic mode, high range
CRL
CR static mode, low range
CRH
CR static mode, high range
CRDL
CR dynamic mode, low range
CRDH
CR dynamic mode, high range
CV
CV mode
CPL
CP static mode, low range
CPH
CP static mode, high range
CVL
CV static mode, low range
CVH
CV static mode, low range
Example
:MODE: CCL
Set the specific channel
to low range constant
current static mode.
Query Syntax
:MODE?
Return Parameter
CCL
CC static mode, low range
CCH
CC static mode, high range
Vue de la page 84