Gw-instek PEL-2000 Series Programming User Manual Manuel d'utilisateur Page 113

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 170
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 112
COMMAND DETAILS
113
Query Syntax
:RESistance:DYNamic:HIGH:FALL? [MIN|MAX]
Return Parameter
<NR2> [MAX|MIN]
Slew rate
1 Unit=1 amp/uS
Returns the slew rate.
MAX/MIN
Returns the allowable
maximum and minimum.
Query Example
:RES:DYN:HIGH:FALL?
MAX
0.8000
For high range dynamic
CR mode, the minimum
value for the falling slew
rate is 0.8 A/uS for the
specific channel.
:RESistance:DYNamic:HIGH:T1/T2
Channel Specific
Command
Description
Sets the timers T1 and T2 for high range dynamic
CR mode.
Syntax
:RESistance:DYNamic:HIGH:T1/T2 <NRf+>[S|ms]
Parameter
<NRf+>[S]
Timer T1/T2
T1/T2 0.1S
Sets the T1/T2 time to 0.1
seconds.
T1/T2 1
Sets T1/T2 to 1 second.
T1/T2 MIN
Sets the T1/T2 to the
minimum value.
T1/T2 MAX
Sets the T1/T2 time to the
maximum time
Example
:RES:DYNA:HIGH:T1 10S
Sets the high range T1
time to 10 seconds for
the specific channel.
Query Syntax
:RESistance:DYNamic:HIGH:T1/T2? [MIN|MAX]
Return Parameter
<NR2> [MAX|MIN]
T1/T2 time.
1 Unit=1 second
Returns T1/T2 time.
MAX/MIN
Returns the allowable
maximum and minimum.
Vue de la page 112
1 2 ... 108 109 110 111 112 113 114 115 116 117 118 ... 169 170

Commentaires sur ces manuels

Pas de commentaire